Daily cleaning and maintenance

1, need: multimeter, hex wrench, adjustable wrench, screwdriver, wiping cloth and other common tools.

2, regular calibration of the scale body, no special circumstances, generally every 1 year should be calibrated.

3, eliminate overload work, so as not to damage the sensor.

4. Regularly clean and check all parts of the scale body to eliminate the fault in the bud.

5, strictly prevent the electrical control box water moisture, to avoid short circuit.

6, in the scale body or its surrounding equipment maintenance when using the welding machine, do not form a current loop between the sensor and the welding wire, otherwise the sensor will be damaged.

7, ensure that the equipment and control box have good electrical grounding.

8, ensure that the platform or steel structure supporting the scale body is stable, do not connect the scale body with the vibrating equipment.

9. Ensure stable and reliable gas and power supply.

10. After the end of work every day, drain the water in the oil-water separator.

11, found problems should be dealt with in time, so as not to expand the fault and affect production.

12, can not use industrial solvents to clean the controller keyboard and display panel.

13, can not produce impact force on the sensor and soak water